Aaeon IMBA-Q87A Instrukcja Użytkownika Strona 41

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 40
3-9
Chapter 3: BIOS setup
Fan Control Mode [Thermal Cruise Mode]
Congurationoptions:[ManualMode][ThermalCruiseMode][SpeedCruise
Mode] [Smart Fan IV Mode]
The following items appear only when you set Fan Control Mode to [Thermal
Cruise Mode].
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Out Stop Value [100]
The Fan Out value decreases to this value if the temperature reaches below
the lowest temperature limit. Input value range: [0~255]
Fan Out Stop Time [60]
Determines the amount of time it takes for the the Fan Out value to fall from
the stop value to zero. Input value range: [0~255]
Critical Temperature [75]
Determines the amount of time Fan Out takes to decrease its value by one
step. Input value range: [0~255]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]
Przeglądanie stron 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 51 52

Komentarze do niniejszej Instrukcji

Brak uwag